Method Validation and Quantitative Estimation of Ethanol using n-Propanol as Internal Standard in whole Blood by Gas Chromatography - Headspace (GC-HS)

Ashok Kumar Jaiswal , Ashok Kumar Jaiswal 1 , Supriya Krishna 2 , Khoob Chand 3 , Tabin Millo 4 , Sudhir Kumar Gupta 5

Author Information

Licence:



Journal of Forensic Chemistry and Toxicology 5(1):p 5-9, . | DOI: http://dx.doi.org/10.21088/jfct.2454.9363.5119.1
How Cite This Article:

Ashok Kumar Jaiswal, Supriya Krishna, Khoob Chand et al. Method Validation and Quantitative Estimation of Ethanol using n-Propanol as Internal Standard in whole Blood by Gas Chromatography - Headspace (GC-HS). J Forensic Chemistry Toxicol. 2019;5(1):5-9.


Received : N/A         Accepted : N/A          Published : N/A

Abstract

Detection and quantification of ethanol in drunken driving cases is of immense importance inforensic toxicology. Despite several analytical methods being available for identification of ethanol in blood, an accurate quantification with minimum sample preparation and rapid analysis is still an ongoing task. The present study evaluates the suitability of Headspace-Chromatography with a capillary column and Flame Ionisation Detector as a method for determining the ethanol content in whole blood samples received for the blood alcohol concentration analysis. An internal standard ‘n-propanol’ was added to the sample to authenticate the results. The peaks areas were measured and calculations were carried out considering peak ratios of analyte to internal standard. The total run time of GC and HS was 20.68 min. The validation study for the method resulted in linearity for a range of 7.9 mg- 237 mg/100 ml, coefficient of variance (R2) was 0.999. Recovery of more than 96% was achieved in spiked samples. LOD and LOQ were 0.20 mg/100 ml and 1.0 mg/100 ml respectively. Blood ethanol measurement by this method is an easy, simple, reliable and reproducible.

 


References

No records found.


Funding


Author Information

Authors and Affiliatione

  • Ashok Kumar Jaiswal
    ,
  • Ashok Kumar Jaiswal 1
    ,
  • Supriya Krishna 2
    ,
  • Khoob Chand 3
    ,
  • Tabin Millo 4
    ,
  • Sudhir Kumar Gupta 5
    ,

Conflicts of Interest

Supplementary Information

Below is the link to the supplementary material.


Rights and Permissions



About this article


Cite this article

Ashok Kumar Jaiswal, Supriya Krishna, Khoob Chand et al. Method Validation and Quantitative Estimation of Ethanol using n-Propanol as Internal Standard in whole Blood by Gas Chromatography - Headspace (GC-HS). J Forensic Chemistry Toxicol. 2019;5(1):5-9.


Licence:



Download citation

Received Accepted Published
N/A N/A N/A
DOI: http://dx.doi.org/10.21088/jfct.2454.9363.5119.1
Keywords GC-HS; Alcohol; ICH Guidelines; FID; Whole Blood etc.

Article Level Metrics

Last Updated

Sunday 08 June 2025, 09:27:29 (IST)


3

Accesses

00
0
00

Citations


22
11
23

View full article metrics including social shares, article views and publishing history


Article Keywords


Keyword Highlighting

Highlight selected keywords in the article text.


Timeline


Received N/A
Accepted N/A
Published N/A

licence



Access this article




Share